The
T1011 Cycle Timer is an enhanced function cycle timer which allows the
user to repetitively turn on and off a 24 VAC output to control any load device
rated at up to 0.8 Amps 20 watt at 24 VAC such as the HGS Engineering D1015 or
D1008 Drivers, or a contactor. The
ON and OFF times are separately adjustable, and are independently selectable for
time adjustments from ½ to 60
seconds, or 30sec to 1 hour. The
T1011 also has a selectable Night Mode feature. In this mode, instead of taking
the OFF time from the OFF TIME control, the unit takes its time from the
NIGHTMODE control which is adjustable from 2 minutes to 4 hours. This is enabled
whenever ambient light drops below a set level.
A. Installation
NOTE: As with all electronic
devices, the T1011 should be plugged into a surge protection device to protect
it from power line surges.
To install the unit, simply plug the load device you wish to switch into the
connector J2 on the bottom right of the unit. Wire the power cord to the
transformer and plug the other end into the connector J1 on the bottom left of
the unit.
Set the On and Off times, and plug the transformer. The T1011 has no On/Off
switch. The unit begins to operate
in the ON TIME mode as soon as the unit is plugged in.
B. Operation
1.
Timer Operation
The T1011 is a cycle timer.
This means that the unit constantly cycles, or alternates between two
modes, an ON TIME mode, and an OFF TIME mode.
In the ON TIME mode, the load device is turned on.
In the OFF TIME, the load device is turned off.
2.
Night Mode Operation
This mode supplements the basic timer operation.
When on, the Timer OFF TIME is replaced with the NIGHT MODE off time.
When this is finished, the ON TIME will start again.
When the ON TIME is finished, another NIGHT MODE off time will start
To enable Night Mode, the Night Mode Switch must be
ON. The unit will operate as before
until the ambient light drops below a set level for more than 15 seconds.
If the unit is in the ON TIME Mode the NIGHT MODE off time will start as
soon as the present ON TIME finishes. If
it is in OFF TIME already, the present OFF TIME will be extended by the NIGHT
MODE off time.
The Night Mode off times continue either until
the Night Mode switch is turned off, or ambient light raises above the set level
for more than 15 seconds. If it is
in the off time, it will immediately start to go into ON TIME Mode no matter how
much time is left.
The 15 second delay prevents Night Mode being
triggered by momentary flashes of light. If
you wish to check something, it will allow you to turn on the lights in the
darkened room for up to 15 seconds when the unit is in the NIGHT MODE off time,
without triggering an immediate ON TIME.
If you want the T1011 to operate with NIGHT
MODE off times all the time regardless of light level, cover the LDR window
beside the ON TIME light with a piece of black tape.
C. Controls
| ON TIME CONTROL |
Adjusts
the time for which the T1011 will turn ON the load device connected to the
output at J2. The full scale range of the control is selectable for either
½ to 60 seconds, or 30 seconds to 60 minutes.
Whenever the red light is On, the output at J2 will be ON. |
| OFF
TIME CONTROL |
Adjusts the time for which the T1011 will turn
OFF the load device connected to the output at J2. The full scale range of
the control is selectable for either ½ to 60 seconds, or 30 seconds to 60
minutes. Whenever the red
light is OFF, the output at J2 will be OFF. |
| NIGHTMODE
CONTROL
|
Adjusts the time for which the T1011 will turn
OFF the load device connected to the output at J2 when in NIGHT MODE. The
full scale range of the control from 2 minutes to 4 hours. |
| ON TIME RANGE
SWITCH
|
Adjusts
the range of the ON TIME control. In SEC position, the control range is
from ½ second to 60 seconds. In MIN position, the control range is from
30 seconds to 60 minutes. |
| OFF
TIME RANGE
SWITCH
|
Adjusts the range of the OFF TIME control. In SEC
position, the control range is from ½ second to 60 seconds. In MIN
position, the control range is from 30 seconds to 60 minutes. |
| NIGHTMODE
SWITCH
|
Turns the Night Mode ON or OFF. |
D.
Specifications
1.
Power Input J1 - 24VAC at 0.8 amps maximum
2.
Output J2 -
24VAC at 0.8 amps maximum
|